Price on application. Pricing on this item moves with supplier rates, so we quote it fresh rather than list a price that goes stale.
Email orders@dzelectricalproducts.com for a current price and availability. Quote the SKU shown on this page and we'll come back to you the same business day.
variable speed drive ATV340 motor: 4 kW 380...480 V - line choke - 1 per drive|ATV31CU22M2 - motor choke - 1 per drive|ATV31CU55N4 - line choke - 1 per drive|ATV31CU55N4 - motor choke - 1 per drive|ATV31CU75N4 - line choke - 1 per drive|ATV61HD11Y - line choke - 1 per drive|ATV61HD15Y - line choke - 1 per drive|ATV61HU30M3 - line choke - 1 per drive|ATV61HU55N4 - line choke - 1 per drive|ATV61HU75N4 - line choke - 1 per drive|ATV61WU55N4 - line choke - 1 per drive|ATV61WU55N4C - line choke - 1 per drive|ATV61WU75N4 - line choke - 1 per drive|ATV61WU75N4C - line choke - 1 per drive|ATV71HD11Y - line choke - 1 per drive|ATV71HD15Y - line choke - 1 per drive|ATV71HU30M3 - line choke - 1 per drive|ATV71HU55N4 - line choke - 1 per drive|ATV71HU75N4 - line choke - 1 per drive|ATV71PU55N4Z - line choke - 1 per drive|ATV71PU75N4Z - line choke - 1 per drive|ATV71WU55N4 - line choke - 1 per drive|ATV71WU75N4 - line choke - 1 per drive|LXM05D42M3X - line choke - 1 per drive|ATV12HU22M2 - motor choke - 1 per drive|ATV12HU22M3 - motor choke - 1 per drive|ATV312HD11S6 - line choke - 1 per drive|ATV312HU22M3 - line choke - 1 per drive|ATV312HU30M3 - line choke - 1 per drive|ATV312HU55N4 - line choke - 1 per drive|ATV312HU75N4 - line choke - 1 per drive|ATV312HU75S6 - line choke - 1 per drive|ATV71HU75S6X - line choke - 1 per drive|ATV312HU22M3 - motor choke - 1 per drive|ATV312HU30M3 - motor choke - 1 per drive|ATV312HU55N4 - motor choke - 1 per drive|ATV312HU75S6 - motor choke - 1 per drive|ATV312HU22M2 - motor choke - 1 per drive|ATV12HU30M3 - motor choke - 1 per drive|ATV12PU22M3 - motor choke - 1 per drive|ATV12PU30M3 - motor choke - 1 per drive|ATV61HU75S6X - line choke - 1 per drive|ATV32HU55N4 - line choke - 1 per drive|ATV32HU75N4 - line choke - 1 per drive|ATV32HU22M2 - motor choke - 1 per drive|ATV32HU55N4 - motor choke - 1 per drive|LXM32.D12N4 - line choke - 1 per drive|LXM32.U60N4 - line choke - 1 per drive|variable speed drive ATV310 motor: 4 kW - line choke - 1 per drive|variable speed drive ATV310 motor: 5.5 kW - line choke - 1 per drive|variable speed drive ATV310 motor: 5.5 kW - motor choke - 1 per drive|variable speed drive ATV340 motor: 5.5 kW 380...480 V - line choke - 1 per drive|variable speed drive ATV340 motor: 7.5 kW 380...480 V - line choke - 1 per drive|variable speed drive ATV320 motor: 5.5 kW 380...500 V - three phase - line choke - 1 per drive|variable speed drive ATV320 motor: 7.5 kW 380...500 V - three phase - line choke - 1 per drive|variable speed drive ATV320 motor: 2.2 kW 200...240 V - single phase - motor choke - 1 per drive|variable speed drive ATV320 motor: 5.5 kW 380...500 V - three phase - motor choke - 1 per drive|variable speed drive ATV320 motor: 2.2 kW 200...240 V - three phase - line choke - 1 per drive|variable speed drive ATV320 motor: 3 kW 200...240 V - three phase - line choke - 1 per drive|variable speed drive ATV320 motor: 2.2 kW 200...240 V - three phase - motor choke - 1 per drive|variable speed drive ATV320 motor: 3 kW 200...240 V - three phase - motor choke - 1 per drive|variable speed drive ATV320 motor: 5.5 kW 525...600 V - three phase - line choke - 1 per drive|variable speed drive ATV320 motor: 7.5 kW 525...600 V - three phase - line choke - 1 per drive|variable speed drive ATV320 motor: 7.5 kW 525...600 V - three phase - motor choke - 1 per drive|variable speed drive ATV630 motor: 11 kW 500...690 V - three phase - line choke - 1 per drive|variable speed drive ATV630 motor: 15 kW 500...690 V - three phase - line choke - 1 per drive|variable speed drive ATV930 motor: 11 kW 500...690 V - three phase - line choke - 1 per drive|variable speed drive ATV930 motor: 15 kW 500...690 V - three phase - line choke - 1 per drive|variable speed drive ATV630 motor: 600 V - three phase - line choke - 10 hp - 1 per drive|variable speed drive ATV630 motor: 600 V - three phase - line choke - 15 hp - 1 per drive|variable speed drive ATV930 motor: 600 V - three phase - line choke - 10 hp - 1 per drive|variable speed drive ATV930 motor: 600 V - three phase - line choke - 15 hp - 1 per drive|variable speed drive ATV310L motor: 0.75 kW|variable speed drive ATV310L motor: 1.5 kW|variable speed drive ATV310L motor: 2.2 kW|variable speed drive ATV310L motor: 3.0 kW|variable speed drive ATV310L motor: 4.0 kW|variable speed drive ATV310L motor: 5.5 kW
Device application
reduction of current harmonics|reduction of overvoltages at motor terminals
3B1 conforming to IEC 721-3-3|3C2 conforming to IEC 721-3-3|3S1 conforming to IEC 721-3-3
Relative humidity
0...95 %
Ambient air temperature for operation
45...55 °C (with current derating of 2 % per °C)|0...45 °C (without current derating)
Ambient air temperature for storage
-25...70 °C
Reach regulation
Free of Substances of Very High Concern above the threshold
Reach free of svhc
Yes
Eu rohs directive
Pro-active compliance (Product out of EU RoHS legal scope)
Toxic heavy metal free
Yes
Mercury free
Yes
Rohs exemption information
Yes
China rohs regulation
X
California proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Others
Package 2 bare product quantity
18
Package 1 bare product quantity
1
Network number of phases
three phase
Value of inductance
2 mH
Thermal losses
75 W
Electrical connection
terminal 6 mm² / AWG 8, 0.8-1 N.m
Supply frequency
50...60 Hz
Max current
1.65 x nominal current (duration = 60 s)
Maximum voltage drop at rated load
5 %
Minimum clearance distance
5.5 mm IEC 60664
Leakage distance
11.5 mm conforming to IEC 60664
Pollution degree
2 conforming to EN 50178
Vibration resistance
1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6|1.5 mm peak to peak (f= 3-13 Hz) conforming to IEC 60068-2-6
Shock resistance
15 gn for 11 ms conforming to IEC 60068-2-27
Operating altitude
<= 1000 m without current derating|1000...3000 m with current derating 1 % per 100 m