{"product_id":"https-www-nhp-com-au-product-kta532ac32","title":"S\u0026S KT5 Motor Protection Circuit Breaker 25 to 32A","description":"\u003cdiv class=\"poa-enquiry\"\u003e\n\u003cp\u003e\u003cstrong\u003ePrice on application.\u003c\/strong\u003e Pricing on this item moves with supplier rates, so we quote it fresh rather than list a price that goes stale.\u003c\/p\u003e\n\u003cp\u003eEmail \u003ca href=\"mailto:orders@dzelectricalproducts.com\"\u003eorders@dzelectricalproducts.com\u003c\/a\u003e for a current price and availability. Quote the SKU shown on this page and we'll come back to you the same business day.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"spec-tables\" class=\"specification-content__Container-sc-141b14e-0 fFkYnc\"\u003e\n\u003cdiv data-testid=\"specification-table\" class=\"spec-table__Container-sc-myqom3-0 ewWXJu\"\u003e\n\u003ch5 class=\"spec-table__Heading-sc-myqom3-1 bFarwo\"\u003eComponent Type (ETIM Class)\u003c\/h5\u003e\n\u003cdiv class=\"grid-container__GridContainer-sc-1rs7zdh-0 spec-table__TableContainer-sc-myqom3-2 cQfTKT anVBn\"\u003e\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003eMotor protection circuit-breaker\u003c\/span\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"specification-table\" class=\"spec-table__Container-sc-myqom3-0 ewWXJu\"\u003e\n\u003ch5 class=\"spec-table__Heading-sc-myqom3-1 bFarwo\"\u003eElectrical\u003c\/h5\u003e\n\u003cdiv class=\"grid-container__GridContainer-sc-1rs7zdh-0 spec-table__TableContainer-sc-myqom3-2 cQfTKT anVBn\"\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eRated permanent current Iu\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003e32 A\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eSwitch off technique\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003eThermomagnetic\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eLong time overload protection adjustment range\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003e25-32 A\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eMax. rated operation voltage Ue\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003e690 V\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eRated short-circuit breaking capacity lcu at 400 V, AC\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003e15 kA\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eRated operation power at AC-3, 400 V\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003e15 kW\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eType of control element\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003eTurn handle\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eType of electrical connection of main circuit\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003eScrew connection\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eNumber of poles\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003e3\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"specification-table\" class=\"spec-table__Container-sc-myqom3-0 ewWXJu\"\u003e\n\u003ch5 class=\"spec-table__Heading-sc-myqom3-1 bFarwo\"\u003eConstruction\u003c\/h5\u003e\n\u003cdiv class=\"grid-container__GridContainer-sc-1rs7zdh-0 spec-table__TableContainer-sc-myqom3-2 cQfTKT anVBn\"\u003e\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eDegree of protection (IP)\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003eIP2X\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"specification-table\" class=\"spec-table__Container-sc-myqom3-0 ewWXJu\"\u003e\n\u003ch5 class=\"spec-table__Heading-sc-myqom3-1 bFarwo\"\u003eMechanical\u003c\/h5\u003e\n\u003cdiv class=\"grid-container__GridContainer-sc-1rs7zdh-0 spec-table__TableContainer-sc-myqom3-2 cQfTKT anVBn\"\u003e\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eMax. tightening torque\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003e2.5 Nm\u003c\/span\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"specification-table\" class=\"spec-table__Container-sc-myqom3-0 ewWXJu\"\u003e\n\u003ch5 class=\"spec-table__Heading-sc-myqom3-1 bFarwo\"\u003eDimensions\u003c\/h5\u003e\n\u003cdiv class=\"grid-container__GridContainer-sc-1rs7zdh-0 spec-table__TableContainer-sc-myqom3-2 cQfTKT anVBn\"\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eHeight\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003e96.8 mm\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eWidth\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003e45 mm\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eDepth\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003e85.5 mm\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv data-testid=\"table-cell\" class=\"spec-table__Cell-sc-myqom3-3 dQdenm\"\u003e\n\u003cspan class=\"spec-table__Label-sc-myqom3-4 iFvAvn\"\u003eWeight\u003c\/span\u003e\u003cspan class=\"spec-table__Value-sc-myqom3-5 hblslX\"\u003e0.33 kg\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"NHP","offers":[{"title":"Default Title","offer_id":49102599913746,"sku":"KTA532AC32","price":0.0,"currency_code":"PHP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0709\/7109\/7362\/files\/KTA532AC32-Motor-Protection-Circuit-Breaker-Photo-PPIP3DL.jpg?v=1715687571","url":"https:\/\/dzelectricalproducts.com\/en-ph\/products\/https-www-nhp-com-au-product-kta532ac32","provider":"DZ ELECTRICAL PRODUCTS","version":"1.0","type":"link"}