Stainless steel enclosure designed to suit an Allen-Bradley switch.
- Model: AB-32-PR
- Material: 304 stainless steel
- Switch: Not included
Product details
Electrix® Rotary Isolator Enclosures without switches, in 304 - V2A - 1.4301 stainless steel, are designed to accommodate rotary isolator switches / disconnects.
The unrivalled quality & aesthetics of Electrix's enclosures have made them the preferred choice of worldwide processing companies for over 35 years.
This IP69K / IP66* polished finish rotary isolator enclosure, with Electrix's unique sealed compartment wall fixing points installed, is 160 x 100 x 100 (H x W x D mm). It has been designed to accommodate an Allen-Bradley Rotary Isolator Switch (up to 32 A - 3 Pole).
Complete with a DIN rail, gasketed lid, captive lid fixing screws, earth terminals & earth link.
Type 1 / 12 / 13 / 4 / 4X*.
Manufacturer specifications
| Material Type |
Stainless Steel |
| Material Grade |
304 - V2A - 1.4301 |
| Material Finish |
Polished |
| Surface Finish (µm Ra) |
< 0.5 |
| Material Thickness (mm) |
1.2 |
| Size (H x W x D mm) |
160 x 100 x 100 |
| Height (mm) |
160 |
| Width (mm) |
100 |
| Depth (mm) |
100 |
| Custom Design |
<p>Custom Designs available on request.</p><ul><li>316L - V4A - 1.4404 material</li><li>Custom sizes</li><li>Pre-lasered cable entry holes & laser cut apertures</li><li>Extra hygienic lid fixing screws</li><li>Security lid fixing screws</li><li>Additional DIN rails</li><li>Alternative switch handle hole configurations</li></ul><a href="/en-gb/stainless-steel-the-custom-shop/" target="_blank">Click here to visit The Custom Shop.</a> |
| Switch Supplied |
No |
| Suitable For |
Allen-Bradley Rotary Isolator, Please contact our Sales Team for more details |
| Maximum Switch Rating (A) |
32 |
| Number of Poles |
3 |
| Suitable as a Motor Disconnect |
No |
| Switch Defeat Mechanism |
No |
| Black Handles |
Sold Separately - Part Number: AB BLACK HANDLE |
| Captive Lid Fixings |
Yes |
| Gasket Material |
UL Recognised Neoprene EPDM Closed Cell (One Piece) |
| Lift-off Lid / Cover |
Yes |
| Fixing Method |
M5 Sealed Wall Fixing Points |
| Internal Wall Fixing Points |
2 |
| DIN Rail |
Fitted |
| DIN Rail Length (mm) |
93 |
| DIN Rail Style |
35 mm (W) x 15 mm (H) - Top Hat |
| DIN Rail Position |
Horizontal / Central |
| Compact Footprint |
Yes |
| Earthing |
Earth terminals & 1 x earth / ground lead* |
| Approvals |
<img alt="cULus Listed" src="/Images/SpecAttributes/spec_logo_cULus_Listed.png" style="padding: 2px 10px 5px 0px;"/><img alt="NSF" src="/Images/SpecAttributes/spec_logo_NSF.png" style="padding: 2px 10px 5px 0px;"/><img alt="IP69K" src="/Images/SpecAttributes/spec_logo_ip69k.png" style="padding: 2px 10px 5px 0px;"/><img alt="Type 4X" src="/Images/SpecAttributes/spec_logo_type_4x.png" style="padding: 2px 10px 5px 0px;"/><img alt="IP66" src="/Images/SpecAttributes/spec_logo_ip66.png" style="padding: 2px 10px 5px 0px;"/><img alt="CE" src="/Images/SpecAttributes/spec_logo_CE_Marking.png" style="padding: 2px 10px 5px 0px;"/><img alt="UKCA" src="/Images/SpecAttributes/spec_logo_UKCA_Marking.png" style="padding: 2px 10px 5px 0px;"/> |
| UL Information |
(Junction & Pull Box) 61ZB, In accordance with UL50/50E, CSA C22.2 No. 94.1 & 2*, File Number: E233528 |
| CE Information |
EN 60670-1, EN 60529, EN 63000 |
| Hygiene Standards |
NSF/ANSI/3A 14159-1 Hygiene Requirements for, the Design of Meat and Poultry Processing Equipment |
| Environmental Rating |
IP66 / IP69K*, Type 1 / 12 / 13 / 4 / 4X* |
| Pack Quantity |
1 |
| Supplied With |
Sealed Compartment Wall Fixing Points, DIN Rail, Lid Gasket, Lid Fixings, Earth Terminals & Earth Link |
| Ideally Suited For |
Food, Dairy, Brewing, Pharmaceutical, Soft Drinks, Architectural companies & many more |
| Alternative Material Finish / Grade |
Satin (Brushed) 304 - V2A - 1.4301 |
| Weight (kg) |
0.95 |
| Fine Print |
*IP / TYPE rating is only maintained when all apertures are adequately sealed. This is an open enclosure unless suitably rated auxiliary devices are installed to fill the openings., , It is the installer's responsibility to check that the earth / ground lead is suitable for the intended application. |
Specifications from Electrix International product data.